Technical Specifications Table
| |
Signal output | 4-20mA / 0-5V / 0-10V / RS485 / (RS485 + analog dual output), etc |
Measure the trip | The 0-10000mm is optional |
Resolution | 16位DA / 16bit / 25,24,26Binary/Cray |
Non-linearity | <±0.02%F.S. (minimum ± 20um) |
Repeatability | <±0.001%F.S. (minimum ± 5um) |
Maximum Reciprocating Speed | 10 m/s |
Update Time | 1 ms (for ranges 1m < L < 2m) / 2 ms (for ranges 2m < L < 3m) |
Operating Temperature | -40°C to +85°C |
Humidity & Dew Point | Humidity 90% , no condensation allowed |
Protection Rating | IP67 |
Pressure Resistance | 35 MPa (continuous) / 70 MPa (peak) |
Input Voltage | 24VDC(±20%) |
Operating Current | <60 mA (varies with range) |
Polarity Protection | Up to -30 VDC |
Overvoltage Protection | Up to 36 VDC |
Insulation Resistance | 500VDC |
Mounting Orientation | Any |
Install thread | Standard: M18×1.5 thread / Customizable: M20×1.5 thread |
Cable Termination | 3051 housing with 3-pin terminal, 4-pin terminal |
Cable Length | 1 meter |
Housing Material | 304 stainless steel |
KYD product outline dimension diagram:

Installation Schematic diagram:

Installation Method for Liquid Tanks
This measurement approach is compatible
with most liquid tanks. The sensor can be
directly threaded into the mounting port
(standard thread: M18×1.5 per ISO 1179-1)
for secure fixation. Key requirements:
1、Vertical Installation Orientation (tolerance: ±2° deviation)
2、Sealing: PTFE tape (EN 751-2 compliant)or O-ring (NBR/FKM material optional)3、Torque: 25–30 N·m (using DIN 3129 standard wrench)
Tel.:19842768572
Hotline:18617045403
E-mail:577595125@qq.com
Add:No. 206 South Seven Road, high-tech Zone, Yuehai Street, Nanshan District, Shenzhen City
WehChat