Technical Specifications Table | |
Signal Output | 4-20mA / 0-5V / 0-10V / RS485 / CANopen / SSI / (Dual analog output) / (RS485 + dual analog output), etc. |
Measuring Range | 0–8000 mm (selectable) |
Resolution | 16位DA / 16bit / 25,24,26Binary/Cray |
Non-linearity | <±0.02%F.S. (minimum ± 20um) |
Repeatability precision | <±0.001%F.S. (minimum ± 5um) |
Maximum reciprocating Speed | 10M/s |
Sefresh time | According to range 1ms (1m <range <2m) 2ms (2m <range <3m) |
Working temperature | -40~ + 85℃ high flexible |
Humidity dew point | Humidity 90%, can not dew |
Levels of protection | IP67 |
Pressure resistance | 24 Mpa (duration) 62 Mpa (peak) |
Lnput voltage | 24VDC(±20%) |
Working current | <60 mA (varying with the range) |
Polarity protection | Max. -30VDC |
Overpressure protection | Maximum of 36VDC |
Lnsulating power | 500VDC |
Installation direction | Any |
way to install | (Standard) M18 * 1.5 (Custom) M20 * 1.5 |
Outline way | Waterproof Connector/Aviation Plug |
Cable length | 1 Meters |
■ RH product outline dimension diagram:
■ RH Installation Schematic diagram:
■RH Installation diagram of oil c
Tel.:19842768572
Hotline:18617045403
E-mail:577595125@qq.com
Add:No. 206 South Seven Road, high-tech Zone, Yuehai Street, Nanshan District, Shenzhen City
WehChat