Technical Specifications Table | |
Signal Output | 4-20mA / 0-5V / 0-10V / RS485 / SSI |
Measuring Range | 0-6000mm(selectable) |
Resolution | 16位DA / 16bit / 25,24,26Binary/Cray |
Non-linearity | <±0.02%F.S. (minimum ± 20um) |
Repeatability precision | <±0.001%F.S. (minimum ± 5um) |
Maximum reciprocating Speed | 10M/s |
Sefresh time | According to range 1ms (1m <range <2m) 2ms (2m <range <3m) |
Working temperature | -40~ + 85℃ high flexible |
Humidity dew point | Humidity 90%, can not dew |
Levels of protection | IP68 |
Pressure resistance | 35 Mpa (duration) 70 Mpa (peak) |
Lnput voltage | 24VDC(±20%) |
Working current | <60 mA (varying with the range) |
Polarity protection | Max. -30VDC |
Overpressure protection | Maximum of 36VDC |
Lnsulating power | 500VDC |
Installation direction | Any |
Install thread | (Standard) M18 * 1.5 (Custom) M20 * 1.5 |
Outline way | Waterproof Connector/Aviation Plug |
Cable length | 1 Meters |
Measuring rod material | Stainless Steel 304/316 (PTFE-Lined) |
■ FH product outline dimension diagram:
■ Installation Schematic diagram:
Installation Method for Liquid Tanks
This measurement approach is compatiblewith most liquid tanks. The sensor can be directly threaded into the
mounting port (standard thread: M18×1.5 per ISO 1179-1)for secure fixation. Key requirements:
1、Vertical Installation Orientation (tolerance: ±2° deviation)
2、Sealing: PTFE tape (EN 751-2 compliant)
or O-ring (NBR/FKM material optional)
3、Torque: 25–30 N·m (using DIN 3129 standard wrench)
Tel.:19842768572
Hotline:18617045403
E-mail:577595125@qq.com
Add:No. 206 South Seven Road, high-tech Zone, Yuehai Street, Nanshan District, Shenzhen City
WehChat