Technical Specifications Table
| |
Signal output | 4-20mA / 0-5V / 0-10V / RS485 / SSI / CANOpen / (analog dual output) / (RS485 + analog dual output), etc |
Measure the trip | The 0-8000mm is optional |
Resolution | 0.5/1/2/5/10/20/40/50/100μm
|
Non-linearity | ±0.01% of full scale, minimum ±50 μm |
Repeatability | ±0.001% of full scale or equal to the resolution, whichever is greater
|
Maximum Reciprocating Speed | 10 m/s |
Update Time | 1 ms (for ranges 1m < L < 2m) / 2 ms (for ranges 2m < L < 3m) |
Operating Temperature | -40°C to +85°C |
Humidity & Dew Point | 90% RH, no condensation allowed |
Protection Rating | IP68 |
Pressure Resistance | 35 MPa (continuous) / 70 MPa (peak) |
Input Voltage | 24VDC(±20%) |
Operating Current | <60 mA (varies with range) |
Polarity Protection | Up to -30 VDC |
Overvoltage Protection | Up to 36 VDC |
Insulation Resistance | 500VDC |
Mounting Orientation | Any |
Install thread | Standard: M18×1.5 thread / Customizable: M20×1.5 thread |
Cable Termination | Waterproof connector / Avi ation plug |
Cable Length | 1 meter |
Housing Material | 304 stainless steel |
PCST product outline dimension diagram:

A | Starting Position |
B | End Position |
C | Effective Length +97 mm |
D | Thread Specification |
E | Effective Length |
Precautions
1、 A magnetostrictive displacement sensor is a magnetic measuring sensor. Avoid strong magnetic fields around the sensor to prevent interference with measurement data.
2、 Route the signal output cables of the magnetostrictive sensor as far away as possible from power cables, high-current circuits and strong pulse interference sources. Check on-site environmental parameters including temperature and vibration to ensure operating conditions comply with the sensor’s rated specifications.
3、 The installation of magnetostrictive displacement sensors includes fixing the sensor body, magnet and cables. The sensor body is mounted via threaded fastening.
4、 Before installation, check that the package is intact and the sensor body is free of obvious bending, dents or impact damage. Install the sensor body according to the specified mounting method.
5、 Use the supplied magnetic isolation gaskets when installing the magnet to maintain a normal magnetic circuit. Wire the cables strictly in accordance with the electrical interface definitions in the manual.
Tel.:19842768572
Hotline:18617045403
E-mail:577595125@qq.com
Add:No. 206 South Seven Road, high-tech Zone, Yuehai Street, Nanshan District, Shenzhen City
WehChat