Technical Specifications Table
| |
Signal Output | Dual analog outputs:0-10V / 10-0V |
Effective Measuring Range | 0-8000mm |
Resolution | 16-bit DA |
Non-linearity | Less than ±0.02% F.S. (minimum ±20 μm) |
Repeatability | Less than ±0.001% F.S. (minimum ±5 μm) |
Max. Reciprocating Speed | 10M/s |
Response Update Time | 1 ms for measuring range of 1 m < Range < 2 m 2 ms for measuring range of 2 m < Range < 3 m |
Operating Temperature | -45~+120℃ |
Humidity & Dew Point | Humidity 90%, can not dew |
IP Rating | IP68 |
Withstand Pressure | 24 MPa (continuous), 60 MPa (peak) |
Input Supply Voltage | 24VDC(±20%) |
Operating Current | < 60 mA (varies with measuring range) |
Reverse Polarity Protection | Max. -30 VDC reverse voltage |
Overvoltage Protection | Max. 36 VDC supply voltage |
Insulation Resistance | 500VDC |
Mounting Orientation | Optional |
Mounting Method | Built-in mounting inside hydraulic cylinder |
Cable Outlet Type | Waterproof connector (IP68) / Plug connection (IP67) |
Cable Length | 2 meters |
■ TH product outline dimension diagram:

Tel.:19842768572
Hotline:18617045403
E-mail:577595125@qq.com
Add:No. 206 South Seven Road, high-tech Zone, Yuehai Street, Nanshan District, Shenzhen City
WehChat