The MPS wire draw displacement sensor, also known as wire draw ruler, wire draw encoder, wire draw
displacement sensor, wire draw crack gauge, crack displacement sensor, wire draw encoder, is a compact
integration of linear displacement sensor structure, fully combining the advantages of angle sensor and linear
displacement sensor. It has a long measurement stroke, small installation space, and high-precision measurement.
The series of wire draw displacement sensors are divided into S: small (0-2500mm maximum stroke selectable),
M: medium (2501-8000mm maximum stroke selectable), and L: large (8001-15000mm maximum stroke selectable).
It has analog current signal mA: 4-20mA, analog voltage signal V1: 0-5V, V2: 0-10V, and pulse signal P: A, B, Z
phase digital output, RS485 digital signal output. It meets the needs of large stroke, high precision, various signal
requirements, and various application occasions.
Technical Parameters | ||
Signal type Parameter items | Digital Signal | Analog Signal |
Measure the trip | 0-15000mm is optional | |
Output Type | Differential, AB phase pulse, RS485 | 0-5/10kΩ、0-5V、 0-10V、4-20mA |
Linear Accuracy | 0.05%FS | 0.1%FS |
Repeat Accuracy | 0.01%FS | |
Resolution | 3600P / 16bit | Infinite resolution |
Maximum Reciprocating Speed | 2000mm/s | |
Cable Length | 1m | |
WireRope | High-flexibility imported coated steel wire rope | |
Outlet Pull Force | 6-10N, the longer the stroke, the greater the pull force | |
Life | ≥5 million reciprocating movements | |
Operating Voltage | DC5V,DC24V, DC10-30V | DC12V,DC15V-DC24V |
Power | Depends on power supply: 0.2W at 12V supply, 0.4W at 24V supply | |
Operating Temperature | -40—85℃ | -45—125℃ |
Protection Level | IP65/IP67 | |
Outer Shell Material | Imported aluminum alloy, surface anti-static interference non-conductive |
● S(0-2500mm)outline dimensional drawing
●M(2501-8000mm)outline dimensional drawing
■ L (8001-1500mm) outline dimensional drawing
■Selection Guide
When selecting a wire draw displacement sensor, one should consider the three elements of stroke, output signal, and installation space:
1、It is recommended to leave a margin when selecting the sensor stroke (the sensor stroke is one specification larger than the actual stroke)。It is strictly forbidden to exceed the stroke.
2、The sensor signal output type shall match the signal type that can be collected by the field acquisition equipment.
3、The on-site installation space should be considered, and a suitable wire draw displacement sensor should be selected.
4、If there are doubts about the selection, you can contact our customer service manager for detailed consultation.
■applied range:
It is mainly suitable for automated measurement occasions such as warehouse location positioning, reservoir dam protection, gate opening control, pressure machinery, paper machinery, textile machinery, metal sheet machinery, packaging machinery, printing machinery, level controllers, construction machinery, industrial robots, injection machines, woodworking machinery, elevators, air compressors, oil presses, height machines, X-Y axes, and other length displacements, liquid level measurements.
■Wiring Definitions
RS485 Communication | Current Output Type (Four-wire System) | Current Output Type (Three-wire System) | |||||
Cable Color | Function Definition | Cable Color | Function Definition | Cable Color | Function Definition | ||
RED | DC12-24V | BROWN | DC15-24V | BROWN | DC15-24V | ||
BLACK | 0V | BIUE | 0V | BIUE | 0V | ||
GREEN | RS485 A | BLACK | output + | BLACK | 4-20mA output | ||
WHITE | RS485 B | WHITE | output- | shield line | GND | ||
shield line | GND | shield line | GND | ||||
Resistor output type | Voltage output type (0-10V) | Current output type (second-line system) | |||||
Cable Color | Function Definition | Cable Color | Function Definition | Cable Color | Function Definition | ||
BROWN | DC5/10V | BROWN | DC15-24V | BROWN | DC12-24V | ||
BIUE | 0V | BIUE | 0V | BLACK | 4-20mA output | ||
BLACK | 0-5K/0-10KΩ | BLACK | 0-10V output | shield line | GND | ||
shield line | GND | shield line | GND | ||||
Differential pulse output | AB phase pulse output | Voltage output type (0-5V) | |||||
Cable Color | Function Definition | Cable Color | Function Definition | Cable Color | Function Definition | ||
RED | DC5V | RED | DC6-24V | BROWN | DC12-24V | ||
WHITE | 0V | BLACK | 0V | BIUE | 0V | ||
BLUE | A+ | GREEN | A | BLACK | 0-5Voutput | ||
GRAY | A- | WHITE | B | shield line | GND | ||
GREEN | B+ | YELLOW | Z | ||||
BROWN | B- | shield line | GND | ||||
YELLOW | Z+ | ||||||
BLACK | Z- | ||||||
shield line | GND |
Description: resistance output type of pull rope displacement sensor is 5V and 10V, output 0-5V and 0-10V voltage signal; voltage
output type and current output type are 15-24V, 12V power supply needs special instructions; RS485 output type is 6-12V, 24V;
pulse output type is 6-30V, and differential signal output needs 5V power output. The sensor shielding line is standard with 1 meter,
default external thread rope head, optional internal thread rope head.
■Instructions for Use
1、Use the bottom fixing screw hole or magnet, according to the needs of the site and machine installation space facilities, directly
install or add protection or other mechanical uses.
2、When installing stainless steel cable, pay attention to the horizontal angle, i.e., try to make the cable from the outlet to the moving
part of the mechanism level when working.
3、Keep a small angle (with a tolerance of +/-3°) to ensure measurement accuracy and the life of the cable. The cable body is
stainless steel coated with a fluorine layer. Do not let it be cut, burned, or impacted by external force. Excessive dust, chips, or
objects that can damage the cable are stored in the internal pulley or outlet, which will cause the cable to be damaged, resulting in
unsmooth operation.
4、Do not pull the cable out by hand or other products and let it instantly snap back without being installed on the workbench or
fixed seat. This action will cause the cable to break, damaging the structure and personal safety.
5、The instant acceleration of reciprocating motion of MPS-S and MPS-M series products should not exceed 2 meters/second; the
instant acceleration of reciprocating motion of MPS-L and MPS-L-P series products should not exceed 1 meter/second. This action
will cause the cable to break, and the company will not bear the responsibility for normal use beyond the scope.
6、If used in non-linear motion mechanisms, please add appropriate pulley operation.
7、If used in harsh or special occasions, please add a protection mechanism by yourself.
Tel.:19842768572
Hotline:18617045403
E-mail:577595125@qq.com
Add:No. 206 South Seven Road, high-tech Zone, Yuehai Street, Nanshan District, Shenzhen City
WehChat